Available Channels - Garner Valley Field Site
| Datalogger | Location | Channel | Depth | Instrument | Calib | Seg. Type | On Date | Description |
|---|---|---|---|---|---|---|---|---|
| GVA01 | 02 | HLV | 0.0150 | fba23_0_5g | 4661.7252 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA01 | 02 | HLL | 0.0150 | fba23_0_5g | 4438.7047 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA01 | 02 | HLT | 0.0150 | fba23_0_5g | 4671.5077 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA01 | 04 | HLV | 0.0500 | fba23_0_5g | 4698.7315 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA01 | 04 | HLL | 0.0500 | fba23_0_5g | 4653.3908 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA01 | 04 | HLT | 0.0500 | fba23_0_5g | 4651.5297 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA02 | 01 | HLV | 0.0060 | fba23_0_5g | 4666.3784 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA02 | 01 | HLL | 0.0060 | fba23_0_5g | 4657.0812 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA02 | 01 | HLT | 0.0060 | fba23_0_5g | 4654.3083 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA02 | 44 | HDD | 0.3330 | kpsi_30_100psi_5v | 0.00032876737 | K | 2007/-12-14 | Pressure Systems 30 Series 5V 100psi/Quanterra 330 |
| GVA02 | 46 | HDD | 0.4170 | kpsi_30_100psi_5v | 0.00032876737 | K | 2007/-12-14 | Pressure Systems 30 Series 5V 100psi/Quanterra 330 |
| GVA02 | 48 | HDD | 0.4940 | kpsi_30_100psi_5v | 0.00032876737 | K | 2007/-02-17 | Pressure Systems 30 Series 5V 100psi/Quanterra 330 |
| GVA03 | 07 | HLZ | 0.0000 | fba23_0_5g | 4656.1626 | A | 2005/-04-15 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA03 | 07 | HLN | 0.0000 | fba23_0_5g | 4676.6484 | A | 2005/-04-15 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA03 | 07 | HLE | 0.0000 | fba23_0_5g | 4660.7956 | A | 2005/-04-15 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA03 | 43 | HDD | 0.0000 | kpsi_30_100psi_5v | 0.00032876737 | K | 2007/-02-17 | Pressure Systems 30 Series 5V 100psi/Quanterra 330 |
| GVA03 | 45 | HDD | 0.3390 | kpsi_30_100psi_5v | 0.00032876737 | K | 2007/-12-14 | Pressure Systems 30 Series 5V 100psi/Quanterra 330 |
| GVA03 | 47 | HDD | 0.4280 | kpsi_30_100psi_5v | 0.00032876737 | K | 2007/-12-14 | Pressure Systems 30 Series 5V 100psi/Quanterra 330 |
| GVA04 | 09 | HLZ | 0.0000 | episensor_10vpg | 18698.781 | A | 2005/-04-15 | Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea |
| GVA04 | 09 | HLN | 0.0000 | episensor_10vpg | 18686.763 | A | 2005/-04-15 | Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea |
| GVA04 | 09 | HLE | 0.0000 | episensor_10vpg | 18688.228 | A | 2005/-04-15 | Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea |
| GVA04 | 10 | HLZ | 0.0000 | fba23_0_5g | 4659.8665 | A | 2005/-04-15 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA04 | 10 | HLN | 0.0000 | fba23_0_5g | 4676.1806 | A | 2005/-04-15 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA04 | 10 | HLE | 0.0000 | fba23_0_5g | 4668.7085 | A | 2005/-04-15 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA05 | 06 | HLV | 0.5010 | fba23_0_5g | 4662.1901 | A | 2006/-01-10 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA05 | 06 | HLL | 0.5010 | fba23_0_5g | 4659.402 | A | 2006/-01-10 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA05 | 06 | HLT | 0.5010 | fba23_0_5g | 4662.6551 | A | 2006/-01-10 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA05 | 65 | HDD | 0.0124 | kpsi_30_45psi_5v | 0.00014794838 | K | 2006/-01-10 | Pressure Systems 30 Series 5V 45psi/Quanterra 330 |
| GVA05 | 69 | HDO | 0.0000 | kpsi_30_20psi_5v_O | 6.575438e-05 | K | 2006/-01-10 | KPSI 30 5V/20psi as Barometer/Quanterra 330 Linear |
| GVA05 | 70 | HDD | 0.0043 | kpsi_30_50psi_5v | 0.00016438142 | K | 2005/-02-09 | Pressure Systems 30 Series 5V 50psi/Quanterra 330 |
| GVA06 | 08 | HLZ | 0.0000 | fba23_0_5g | 4676.1806 | A | 2007/-12-14 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA06 | 08 | HLN | 0.0000 | fba23_0_5g | 4676.1806 | A | 2007/-12-14 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA06 | 08 | HLE | 0.0000 | fba23_0_5g | 4676.1806 | A | 2007/-12-14 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA06 | 12 | HLZ | 0.0000 | mems_1000hz_3g_1-2vg | 18645.114 | A | 2004/-08-12 | Applied Mems SF3000L 1000 Hz 1.2 Volt per g/Quante |
| GVA06 | 12 | HLN | 0.0000 | mems_1000hz_3g_1-2vg | 18719.629 | A | 2004/-08-12 | Applied Mems SF3000L 1000 Hz 1.2 Volt per g/Quante |
| GVA06 | 12 | HLE | 0.0000 | mems_1000hz_3g_1-2vg | 18152.933 | A | 2004/-08-12 | Applied Mems SF3000L 1000 Hz 1.2 Volt per g/Quante |
| GVA07 | 03 | HLV | 0.0220 | fba23_0_5g | 4673.843 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA07 | 03 | HLL | 0.0220 | fba23_0_5g | 4671.041 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA07 | 03 | HLT | 0.0220 | fba23_0_5g | 4678.9979 | A | 2003/-11-08 | KMI FBA23 50 Hz FS 0.5g/Quanterra 330 Linear Phase |
| GVA07 | 61 | HDD | 0.0027 | paro_pt_250 | 9.5367523e-06 | K | 2004/-10-20 | Paroscientific Pressure Transducer/Quanterra 330 L |
| GVA07 | 62 | HDD | 0.0019 | paro_pt_250 | 9.5367523e-06 | K | 2004/-10-20 | Paroscientific Pressure Transducer/Quanterra 330 L |
| GVA07 | 63 | HDD | 0.0059 | paro_pt_250 | 9.5367523e-06 | K | 2004/-10-20 | Paroscientific Pressure Transducer/Quanterra 330 L |
| GVA08 | 60 | HDD | 3.5000 | paro_pt_250 | 9.5367523e-06 | K | 2006/-01-10 | Paroscientific Pressure Transducer/Quanterra 330 L |
| GVDA | 00 | HLZ | 0.0000 | episensor_10vpg | 18676.37 | A | 2005/-03-14 | Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea |
| GVDA | 00 | HLN | 0.0000 | episensor_10vpg | 18680.76 | A | 2005/-03-14 | Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea |
| GVDA | 00 | HLE | 0.0000 | episensor_10vpg | 18680.907 | A | 2005/-03-14 | Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea |
| GVDA | 05 | HLZ | 0.1500 | episensor_10vpg | 2343.2515 | A | 2006/-01-10 | Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea |
| GVDA | 05 | HLN | 0.1500 | episensor_10vpg | 2346.2954 | A | 2006/-01-10 | Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea |
| GVDA | 05 | HLE | 0.1500 | episensor_10vpg | 2338.7921 | A | 2006/-01-10 | Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea |
Channel Name Encoding:
| Letter # | Usage | Value Range |
|---|---|---|
| 1 | Band Code |
H - High Broad Band, 200sps B - Broad Band, 40sps L - Long Period, 1sps |
| 2 | Instrument Code |
L - Low Gain Seismometer D - Pressure Transducer |
| 3 | Orientation Code |
Z - Vertical (up/down) N - Lateral (North/South) E - Transverse (East/West) V - Vertical L - Lateral T - Transverse O - Outside barometer |
| CSS Seg Type: |
A - acceleration K - kilo pascal P - millibar t - temperature |