Available Channels - Wildlife Refuge Field Site

Datalogger Location Channel Depth (km) Instrument Calib Seg. Type On Date Description
WLA 00 HNE 0.0000 episensor_10vpg 18721.246 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 00 HNN 0.0000 episensor_10vpg 18688.228 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 00 HNZ 0.0000 episensor_10vpg 18688.228 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 01 HNE 0.0025 episensor_10vpg 18728.746 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 01 HNN 0.0025 episensor_10vpg 18700.248 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 01 HNZ 0.0025 episensor_10vpg 18674.907 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 02 HNE 0.0055 episensor_10vpg 18697.168 A 2007-04-26 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 02 HNN 0.0055 episensor_10vpg 18689.839 A 2007-04-26 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 02 HNZ 0.0055 episensor_10vpg 18713.751 A 2007-04-26 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 03 HNE 0.0055 episensor_10vpg 18703.181 A 2005-02-08 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 03 HNN 0.0055 episensor_10vpg 18697.168 A 2005-02-08 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 03 HNZ 0.0055 episensor_10vpg 18733.161 A 2005-02-08 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 04 HNE 0.0077 episensor_10vpg 18712.136 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 04 HNN 0.0077 episensor_10vpg 18688.228 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 04 HNZ 0.0077 episensor_10vpg 18697.168 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 05 HNE 0.0300 episensor_10vpg 18674.907 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 05 HNN 0.0300 episensor_10vpg 18694.236 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 05 HNZ 0.0300 episensor_10vpg 18686.763 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 06 HNE 0.1000 episensor_10vpg 18692.77 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 06 HNN 0.1000 episensor_10vpg 18704.649 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 06 HNZ 0.1000 episensor_10vpg 18691.305 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 10 HNE 0.0000 episensor_10vpg 18700.248 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 10 HNN 0.0000 episensor_10vpg 18680.76 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 10 HNZ 0.0000 episensor_10vpg 18724.186 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 11 HNE 0.0000 episensor_10vpg 18682.37 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 11 HNN 0.0000 episensor_10vpg 18703.181 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 11 HNZ 0.0000 episensor_10vpg 18703.181 A 2004-09-24 Episensor 200 Hz 10 Volt per g/Quanterra 330 Linea
WLA 60 HDD 0.0027 paro_pt_250 9.5367523e-06 K 2004-09-24 Paroscientific Pressure Transducer/Quanterra 330 L
WLA 61 HDD 0.0029 paro_pt_250 9.5367523e-06 K 2004-09-24 Paroscientific Pressure Transducer/Quanterra 330 L
WLA 62 HDD 0.0034 paro_pt_250 9.5367523e-06 K 2004-09-24 Paroscientific Pressure Transducer/Quanterra 330 L
WLA 63 HDD 0.0037 paro_pt_250 9.5367523e-06 K 2004-09-24 Paroscientific Pressure Transducer/Quanterra 330 L
WLA 64 HDD 0.0042 paro_temp_40C 5.9604702e-05 t 2005-02-04 Paroscientific Pressure Transducer - Temperature M
WLA 65 HDD 0.0044 paro_pt_250 9.5367523e-06 K 2004-09-24 Paroscientific Pressure Transducer/Quanterra 330 L
WLA 66 HDD 0.0064 paro_pt_250 9.5367523e-06 K 2005-02-04 Paroscientific Pressure Transducer/Quanterra 330 L
WLA 67 HDD 0.0064 paro_pt_250 9.5367523e-06 K 2004-09-24 Paroscientific Pressure Transducer/Quanterra 330 L
WLA 69 HDO 0.0000 kpsi_30_20psi_5v_O 6.575438e-05 K 2004-09-24 KPSI 30 5V/20psi as Barometer/Quanterra 330 Linear
WLA 70 HDD 0.0043 kpsi_30_50psi_5v 0.00016438142 K 2005-02-04 Pressure Systems 30 Series 5V 50psi/Quanterra 330

Channel Name Encoding:

Letter # Usage Value Range
1 Band Code H - High Broad Band, 200sps
B - Broad Band, 40sps
L - Long Period, 1sps
2 Instrument Code N - Accelerometer
H - Seismometer
D - Pressure Transducer
3 Orientation Code Z - Vertical (up/down)
N - Lateral (North/South)
E - Transverse (East/West)
V - Vertical
L - Lateral
T - Transverse
O - Outside barometer
   CSS Seg Type: A - acceleration
K - kilo pascal
P - millibar
t - temperature